Document
Semiconductor thermogenerator - Seebeck effect
Item no.: P2410700
In a semi-conductor thermogenerator, the no-load voltage and the short-circuit current are measured as a function of the temperature difference. The internal resistance, the Seebeck coefficient and the efficiency are determined.
영문 설명서
Tasks

1. To measure no-load voltage U0 and short-circuit current Is at different temperature differences and to determine the Seebeck coefficient.
2. To measure current and voltage at a constant temperature difference but with different load resistors, and to determine the internal resistance Ri from the measured values.
3. To determine the efficiency of energy conversion, from the quantity of heat consumed and the electrical energy produced per unit time.
학습목록

  • Seebeck effect (thermoelectric effect)
  • Thermoelectric e.m.f.
  • Efficiency
  • Peltier coefficient
  • Thomson coefficient
  • Seebeck coefficient
  • Direct energy conversion
  • Thomson equations
장점

  • Open design allows to fully understand function and applications
  • Individual instruments for distinct functions (no "black box")
  • Key products of the experiment setup can also be used for investigating the Peltier effect
문의

  • 제품 상담 : 직통번호(070-8645-2312)
  • 팩스, 게시판, 이메일을 통해 견적문의할 수 있습니다.
    견적작성 시 필요하니 성함(업체명), 연락처, 이메일 주소 등을 남겨주세요. 감사합니다.
    - 이메일 : info@koreasci.com
    - 팩스 : 02-929-0966
    - 게시판 바로가기
배송

    이 제품은 결제완료 후 해외에서 배송됩니다. 해외 물품의 재고 여부에 따라 배송기간이 달라집니다.